Stand alone Sets

CO2 Alert Mk10 Detector SET 2 A
CO2 Alert Mk10 Detector SET 2 A
Order Reference : 2025
CO2 Alert Mk10 Detector SET 2 A
The LogiCO2 ALERT is a CO2 monitor with integrated sound and light Alarm indication, designed to measure CO2 concentration in a confined space environment. It provides an alarm in the event that a CO2 level considered unhealthy/dangerous is measured, in the area being monitored. This plug and play set contains a stainless steel bar to protect the sensor and an additional warning Horn/Strobe.
Read more
CO2 Alert Mk10 Kiosk
CO2 Alert Mk10 Kiosk
Order Reference : 2018
CO2 Alert Mk10 Kiosk
The LogiCO2 ALERT is a CO2 monitor with integrated sound and light Alarm indication, designed to measure CO2 concentration in a confined space environment. It provides an alarm in the event that a CO2 level considered unhealthy/dangerous is measured, in the area being monitored. This set contains a stainless steel bar to protect the sensor.
Read more

CO2 Safety System Set

CO2 MK9 Detector SET 4 A
CO2 MK9 Detector SET 4 A
Order Reference : 2049
CO2 MK9 Detector SET 4 A
The Carbon Dioxide (CO2) Safety System MK9 is designed to measure CO2 concentration in a confined space environment. It is designed to provide an alarm in the event that a CO2 level considered dangerous is measured, in the area being monitored. This complete plug and play set contains a MK9 CO2 Sensor, a MK9 Central Unit to display the measured values and a Horn/strobe.
Read more

Extra Sensor Kits

(Please note that the Mk9 and Mk10 can be connected in the same system)

CO2 Alert Mk10 Sensor KIT
CO2 Alert Mk10 Sensor KIT
Order Reference : 2100
CO2 Alert Mk10 Sensor KIT
This CO2 Alert Mk10 Kit can be used to add a CO2 sensor to an existing MKVII, MK9 or MK10 Set. It contains a CO2 Alert MK10 Detector, a Horn/strobe, a stainless steel bar to protect the sensor, the cables and connectors required for the connections and the signs.
Read more
CO2 MK9 Sensor KIT
CO2 MK9 Sensor KIT
Order Reference : 2117
CO2 MK9 Sensor KIT
This CO2 Mk9 Kit can be used to add a sensor to an existing MKVII, MK9 or MK10 Set. It contains a CO2 M9 Detector, a Horn/strobe, the cables and connectors required for the connections and the signs.
Read more

Central Unit Kit

CO2 Central Unit MK9 KIT 4A
CO2 Central Unit MK9 KIT 4A
Order Reference : 0328
CO2 Central Unit MK9 KIT 4A
This Central Unit Kit contains a MK9 Central Unit, the cables and the connectors needed to add a Central Unit to an existing MKVII, MK9 or MK10 installation without a Central Unit already installed. The MK9 Central unit can display the values, the alerts and the error messages of 1 to 8 MK7, MK9 or MK10 CO2 Sensors. The “CO2 Alert Mk10 Detector Set C” is not delivered with a communication cable => it is not compatible with this Kit.
Read more

Extra Warning Kits

EXTRA HORN/STROBE LED KIT
EXTRA HORN/STROBE LED KIT
Order Reference : 1172
EXTRA HORN/STROBE LED KIT
HORN/STROBE LED is a combined horn and strobe.
Observe!
The Horn/Strobe has two separate inputs, one for low alarm – Flashing Strobe and one for high alarm – Sounding Horn.
The Horn/Strobe is delivered with 1 meter (3 feet) preconnected cable, a splitter, an extra 10 meter (33 feet) connection cable and a warning sign.
Read more
Specifications
OAK BROOK KIT 2
OAK BROOK KIT 2
Order Reference : 0472
OAK BROOK KIT 2
One extra Horn/Strobe and Beacon
Read more
Specifications
OAK BROOK KIT 3
OAK BROOK KIT 3
Order Reference : 0489
OAK BROOK KIT 3
Two extra Horn/Strobes and one Beacon to upgrade older MKVII B installations
Read more
Specifications

Central Units & Sensors

Central Unit MK9
Central Unit MK9
Order Reference : 0311
Central Unit MK9
Central Unit for monitoring up to eight CO2 sensors.
• Displays results of sensor unit measurements.
• Controls the operation of the system.
Read more
CO2 SENSOR MK9
CO2 SENSOR MK9
Order Reference : 1134
CO2 SENSOR MK9
Sensor for CO2 monitoring.
• Display alternates between CO2 (0.0%-6.0%), TWA (ppm) and temperature.
• Displays measurement results and alarm indications.
Read more

Light & Sound

FLASH-24-R
FLASH-24-R
Order Reference : 0403
FLASH-24-R (Weather proof)
24V warning lamp for CO2 Safety System, incl 1m cable.
FLASH-24-R is a warning beacon, an high intensity LED warning lamp with built in Klicking Sounder System.
Read more
Specifications
Power supply:
10-60V DC +/- 1+%
Average current:
88 mA @ 24V DC supply
Flash energy:
2 Joule
Flash frequency:
60/min
Ambient temperature:
-10°C...70°C (14°F...158°F)
Dimensions/ mm:
Ø 91 x Height 96 mm
Dimensions/ ":
Ø 3.6’’ x Height 3.8’’
Ingress protection:
IP 54
HORN/STROBE LED
HORN/STROBE LED
Order Reference : 0434
HORN/STROBE LED
24V warning Horn/Strobe for Carbon Dioxide configured for the CO2 Sensors, incl. 1m cable.
Horn/Strobe is a loud warning horn and high intensity Strobe.
Read more
Specifications
TRAFFIC LIGHT
TRAFFIC LIGHT
Order Reference : 0427
TRAFFIC LIGHT
24 V "Traffic Light" and Horn configured for MkVII, Mk9 and Mk10 CO2 Sensors, incl. 1 m cable.
Continuous green light indicates that the sensor is running. The orange light is blinking when alarm level 1 is reached. The red light is blinking and the horn is sounding when alarm level 2 is reached.
Read more
Specifications
SIREN-24-R
SIREN-24-R
Order Reference : 0458
SIREN-24-R
Siren 24V for CO2 Safety System, incl cable.
Extra loud warning siren for high alarm indication.
Read more
Specifications
Power supply:
9-28V DC +/- 10%
Average current:
28 mA @ 24V DC supply
Decibel:
111 dBA / 1 m
Dimensions (LxWxD) / mm:
Ø 91 x Height 94 mm
Dimensions (LxWxD) / ":
Ø 3.6’’ x Height 3.7’’
Ingress protection:
IP 54

Relay

Remote Connection Box
Remote Connection Box
Order Reference : 0465
Remote Connection Box
Remote Connection Box for CO2 Safety System. In many places it has become standard with remote connection to fire departments through the normal existing fire alarm system. It can also be used to run external ventilation.
Read more
Specifications
Power supply:
Via CO2 Sensor
Relays:
1A/24V AC/DC
Material:
PC/ABS
Dimensions (WxHxD):
78x78x37 mm
Ingress protection:
IP 20

Cable & connectors

RJ45 CABLE R5M
RJ45 CABLE R5M
Order Reference : 0717
RJ45 CABLE R5M
5m red RJ45 cable for the LogiCO2 Safety Systems.

The RJ 45 cables for the CO2 Safety Systems are either blue or red. The red side is for power and communication and the blue side is for warning signaling. All connectors are marked with either a blue mark or a red one.
Read more
Specifications
Cable specification:
CAT5 AWG24
Cable contact:
RJ45
RJ45 CABLE R10M
RJ45 CABLE R10M
Order Reference : 0724
RJ45 CABLE R10M
10m red RJ45 cable for the LogiCO2 Safety Systems.

The RJ 45 cables for the CO2 Safety Systems are either blue or red. The red side is for power and communication and the blue side is for warning signaling. All connectors are marked with either a blue mark or a red one.
Read more
Specifications
Cable specification:
CAT5 AWG24
Cable contact:
RJ45
RJ45 CABLE B5M
RJ45 CABLE B5M
Order Reference : 0731
RJ45 CABLE B5M
5m blue RJ45 cable for the LogiCO2 Safety Systems.

The RJ 45 cables for the CO2 Safety Systems are either blue or red. The red side is for power and communication and the blue side is for warning signaling. All connectors are marked with either a blue mark or a red one.
Read more
Specifications
Cable specification:
CAT5 AWG24
Cable contact:
RJ45
RJ45 CABLE B10M
RJ45 CABLE B10M
Order Reference : 0748
RJ45 CABLE B10M
10m blue RJ45 cable for the LogiCO2 Safety Systems.

The RJ 45 cables for the CO2 Safety Systems are either blue or red. The red side is for power and communication and the blue side is for warning signaling. All connectors are marked with either a blue mark or a red one.
Read more
Specifications
Cable specification:
CAT5 AWG24
Cable contact:
RJ45
RJ45 1-1 EXTENSION
RJ45 1-1 EXTENSION
Order Reference : 0519
RJ45 1-1 EXTENSION
Extension connector
Read more
Specifications
RJ45 1-2 SPLIT
RJ45 1-2 SPLIT
Order Reference : 0526
RJ45 1-2 SPLIT
RJ45 splitter 1-2
Read more
Specifications
RJ45 1-4 SPLIT
RJ45 1-4 SPLIT
Order Reference : 0540
RJ45 1-4 SPLIT
RJ45 splitter 1-4
Read more
Specifications

Stainless Steel Protection Bar

Protection Bar for CO2 Alert Mark 10
Protection Bar for CO2 Alert Mark 10
Order Ref : 0199
Stainless Steel Protection Bar For CO2 Alert Mark 10
Read more
Specifications
Protection Bar for CO2 Sensor MK9
Protection Bar for CO2 Sensor MK9
Order Reference : 0182
Stainless Steel Protection Bar For CO2 Sensor MK9
Read more
Specifications

Power Supply

Power Supply 1A
Power Supply 1A
Order Reference : 0021
Power Supply 1 Amp
Transformer for CO2 Safety System (max 1 Amp).
Read more
Specifications

Computer Interface

USB-MODBUS INTERFACE
USB-MODBUS INTERFACE
Order Reference : 0953
USB-MODBUS INTERFACE
In combination with the LogiCO2 software, this USB-MODBUS interface enables to view and log CO2 levels measured by the LogiCO2 CO2 Sensors on a computer.
Read more

Mk7 CO2 System now replaced by Mk9 and Mk10 products which are completely compatible with each other

CO2 SET1 CE MKVII C
CO2 SET1 CE MKVII C
CO2 Safety System, Set1 MKVII, (Celcius), incl warning lamp and horn/strobe
The Carbon Dioxide (CO2) Safety System is designed to measure CO2 concentration in a confined space environment. It is designed to provide an alarm in the event that a CO2 level considered dangerous is measured, in the area being monitored.
Read more
CO2 SET1 UL MKVII B
CO2 SET1 UL MKVII B
CO2 Safety System MKVII, Set1, (Farenheit), incl warning lamp and siren
The Carbon Dioxide (CO2) Safety System is designed to measure CO2 concentration in a confined space environment. It is designed to provide an alarm in the event that a CO2 level considered dangerous is measured, in the area being monitored.
Read more
Specifications
See Pdf manual for details.
CO2 SENSOR SET CE C
CO2 SENSOR SET CE C
Extra CO2 Sensor incl. warning lamp
Extra CO2 sensor set for adding extra sensors to the basic MkVII SET. The sensor is pre-programmed with ID 2. The set comes with signs, cables and warning signalisation.
Read more
Specifications
CO2 CENTRAL UNIT III
CO2 CENTRAL UNIT III
CO2 CENTRAL UNIT III
Central Unit for monitoring up to four CO2 sensors.
• Displays results of sensor unit measurements.
• Controls the operation of the system.
Read more
Specifications
Power supply:
12-24V DC
Approval:
the iCE: Emission tests according SS-EN 61000-6-3 and the immunity tests
Ingress protection:
IP 20
Ambient temperatures:
0-40°C (+32°F...102°F)
Humidity:
0-90% non-condensing
Acustic signal-strength:
70 dB (1m) max.
Display:
Two rows: 2 x 8 digit
Communication:
RS485, Modbus
Current consumption:
40 mA
Dimensions (LxWxD):
98 x 66 x 41 mm
Central Unit for monitoring up to four CO2 sensors.
• Displays results of sensor unit measurements. • Controls the operation of the system. • Displays measurement results and alarm indications. • The display alternates between CO2 (0.0%-10.0%), TWA (ppm) and temperature.
If more sensors are connected the values from them is also displayed indicating which sensor the value is from.
• The display also shows what kind of alarm is activated and also the error code when an error is being indicated.
• The central unit also has LEDs indicating that the unit is on (green LED), error (yellow LED). and Alarm/Alert (red LED).
A buzzer sounds when there is a error or alarm/ alert. Error and alerts are indicated by a intermittent sound and alarm
by a continuous sounding buzzer.
• Under the right bottom side of the unit there is a sound mute / reset button. Muting is done by quickly pressing the button, resetting is accomplished by pressing the button until the text Cleared appears on the display together with short beeps.
CO2 SENSOR CE MKVII
CO2 SENSOR CE MKVII
CO2 SENSOR CE MKVII
Sensor for CO2 monitoring.
• Display alternates between CO2 (0.0%-10.0%), TWA (ppm) and temperature.
• Displays measurement results and alarm indications.
Read more
Specifications
Power supply:
12-24V DC
Measurement range temp:
0 to +40oC (Celcius)
Measurement range CO2:
0-3 Vol.%
Extended range CO2:
3-10 Vol.%
Display:
4 digit LCD display
Gas sampling mode:
Diffusion
Dimensions (LxWxD)
180 x 100 x 52 mm / 7” x 4” x 2”
• Red LED lights when CO2 concentration is at or above 1.5% (depending on local legislation).
• Yellow LED lights when there is a error code. A wrench is also shown on the digital display.
• Green LED lights when the system is active.
At the low alarm level the tone may be switched off by pressing the reset button shortly. At a low alarm, the red LED will con- tinue until the CO2 level drops below 1.5% (the low alarm). At a Low Alarm, one person, supervised by another, may check for the leakage cause. If ambient conditions at the sensor reach a concentration level of 3% or more, the central unit’s main alarm will activate emitting a constant audible tone, the red LED will light and the digital display will read ALARM.
The room in which the sensor is located must not be entered when the CO2 concentration is over 3%! A CO2 Service agent must be contacted!
LogiCO2 International AB / LogiCO2 International SARL. / LogiCO2 Online SARL.
Telephone +352-320 872 · Fax +352-2632 0398 · info@logico2.com